Industrial PWHT Machine

Compact design, ideal for local repairs, small-bore piping, and emergency on-site thermal applications.

  • Advanced Thermal Control: Utilizing high-precision PID controllers to manage heating rates, soak times, and cooling phases, ensuring a stable thermal cycle within ± 5°C accuracy.
  • Robust Industrial Design: Built for durability in demanding field environments, with high-grade electrical components and advanced safety interlocks to prevent overheating.
  • Compliance & Traceability: Full digital recording of all thermal cycles, providing the necessary documentation for QA/QC inspectors and third-party audit compliance.

Key Specifications

Temperature Range: Ambient to 1200°C (Customizable)
Control Accuracy: ± 1% of Full Scale
Standard Compliance: ASME Section VIII, ASME Section V

1-Channel PWHT Unit

Product code Power Power Supply Output Voltage Maximum Element can connect to machine Maximum power for each channel Output type
HSP1-8-C 8 KW Single Phase 220V 60V 2 8 KW Contactor
HSP1-8-S 8 KW Single Phase 220V 60V 2 8 KW SSR
HSP1-8-V 8 KW Single Phase 220V From 0 to 60V 2 8 KW SCR
HSP1-16-C 16 KW Three Phase 380V 60V 4 16 KW Contactor
HSP1-16-S 16 KW Three Phase 380V 60V 4 16 KW SSR
HSP1-16-V 16 KW Three Phase 380V From 0 to 60V 4 16 KW SCR
HSP1-0220-C 10 KW Single Phase 220V 220V 4 10 KW Contactor
HSP1-0380-C+ 20 KW Three Phase 380V 220V or 380V 4 or 7 20 KW Contactor
HSP1-0220-V 10 KW Single Phase 220V From 0 to 220V 4 10 KW SCR
HSP1-0380-V+ 20 KW Three Phase 380V From 0 to 380V 8 20 KW SCR
Click to view full coding breakdown details

Product Coding System

HSP A BCD EF /G
Segment Meaning Details
AOutput Channels1, 3, 6, 12
BCDMachine Power8, 16 (HSP1), 25 (HSP3), 50 (HSP3/6), 75/100 (HSP6/12), 150 (HSP12), 0220/0380 (All)
EFOutput KindC (Contactor), S (SSR), V (SCR-220V), C+ (Swap), V+ (SCR-380V)
/GAdd. InputOptional input expansion up to 200 TCs